Winter fog and rooftop solar in Lucknow and Shahjahanpur: modelled units per kW for December and January
By BL Solar Solutions · Reviewed by Aditya KumarUpdated · 12 sources
In this article (4 sections)
How much does winter fog cut solar output? In a long-term model from the European Commission's PVGIS tool, 1 kW of south-facing solar panels tilted at 26° makes about 4.5 to 4.6 units (kWh) a day in December and January, in both Lucknow and Shahjahanpur. That is slightly above the model's yearly average of about 4.3 units a day, and below its March peak of about 5.2. A 3 kW system would make about 13.6 to 13.9 units a day in those months. These are averages from a model, not measurements. A foggy or smoggy day can make much less. In the model, the weakest months are July and August, not winter.

The figures come from PVGIS, a free solar tool run by the European Commission's Joint Research Centre (JRC). They are modelled, not measured. They are not readings from BL Solar installations or from any particular home. How the model was set up, and what it leaves out, is explained below.
Units per day and per month, month by month
Modelled with PVGIS, not measured. 1 kW of crystalline silicon panels, facing south, tilted 26°, with PVGIS's default 14% system loss. Each figure is the average for that month over 2005 to 2023. Months run April to March, the same year UP uses to settle net metering.
| Month | Lucknow, units a day | Shahjahanpur, units a day | Lucknow, units a month | Shahjahanpur, units a month |
|---|---|---|---|---|
| April | 5.10 | 5.12 | 153 | 154 |
| May | 4.72 | 4.77 | 146 | 148 |
| June | 3.90 | 4.05 | 117 | 121 |
| July | 2.91 | 2.98 | 90 | 92 |
| August | 3.12 | 3.17 | 97 | 98 |
| September | 3.63 | 3.72 | 109 | 111 |
| October | 4.50 | 4.61 | 140 | 143 |
| November | 4.63 | 4.66 | 139 | 140 |
| December | 4.55 | 4.52 | 141 | 140 |
| January | 4.62 | 4.55 | 143 | 141 |
| February | 5.01 | 4.98 | 140 | 140 |
| March | 5.17 | 5.16 | 160 | 160 |
| Whole year | 4.32 a day on average | 4.35 a day on average | 1,575 a year | 1,589 a year |
February has fewer days, so its monthly total is lower even though each day is better.
What the model shows:
- December and January sit slightly above the yearly average. In Lucknow, December is about 5% and January about 7% above it. In Shahjahanpur, about 4% and 5%.
- They are below spring. December gives about 12% less per day than March in both cities.
- The lowest months are July and August, at about 2.9 to 3.2 units a day.

Representative image
A 3 kW example (estimate)
A 3 kW system makes three times the 1 kW figures. This is an estimate from the model, not a promise of output.
| 3 kW system (estimate) | Lucknow | Shahjahanpur |
|---|---|---|
| December, units a day | 13.65 | 13.56 |
| January, units a day | 13.86 | 13.65 |
| Yearly average, units a day | 12.96 | 13.05 |
| December, units in the month | 424 | 420 |
| January, units in the month | 429 | 423 |
| Whole year, units | 4,726 | 4,766 |
UPNEDA, the state's renewable energy agency, gives figures in the same range. Its PM Surya Ghar booklet says a 1 kW rooftop plant "typically generates 4 to 5 units of electricity daily". Its rooftop solar FAQ says 1 kW can make 4 to 5.5 units "on a clear sunny day", and that a 2 kW system averages 270 units a month in UP, which works out to about 4.5 units a day per kW.
Why winter fog and short days cut solar output
Shorter days and a lower sun
Around 21 December, Lucknow gets about 10 hours 27 minutes of daylight, against about 13 hours 50 minutes around 21 June. At noon in late December the sun is only about 40° above the horizon, against about 87° in late June. Shahjahanpur is almost the same. These are estimates worked out with the method the US National Oceanic and Atmospheric Administration (NOAA) publishes for its sunrise and sunset calculator.
On flat ground, this makes December the darkest month. PVGIS puts the sunlight falling on a flat surface in Lucknow at about 3.96 kWh per square metre a day in December, the lowest of any month, against 7.17 in May.
Panels tilted towards the south catch more of the low winter sun. On a panel tilted at 26°, the same December sunlight becomes about 5.82 kWh per square metre a day. That is why a tilted rooftop system loses much less in winter than the flat-ground figure suggests.
The tilt of your structure matters. In the same model, panels tilted at only 10° make about 3.72 units a day per kW in a Lucknow December, about 18% less than at 26°. Over the whole year the gap is only about 5%. MNRE's technical specifications for PM Surya Ghar ask for a tilt that gives the most energy over the year, and allow a flatter tilt to fit more panels on a roof as long as the system still meets its performance requirement. If your panels are flatter than 26°, expect a deeper winter dip than the table shows.
Fog, haze and smog
A paper published in July 2026 in MAUSAM, the journal of the India Meteorological Department (IMD), describes fog as cloud at surface level that cuts visibility to under 1,000 metres. It says fog is an important weather feature from November to February, that the Indo-Gangetic plains of north India see major fog in this period, and that the conditions for it are often met in the late night and morning hours.
UP sees dense fog in this season. On 28 December 2025, IMD reported dense to very dense fog, with visibility under 50 metres, in parts of Uttar Pradesh. It warned of dense to very dense fog during night and morning hours over west UP until 31 December and east UP until 1 January.
Fog and haze cut the sunlight that reaches a panel:
- The JRC explains that sunlight is absorbed and scattered on its way through the air by particles such as aerosols and by water vapour, and that the main cause of this loss is cloud cover.
- A 2021 release from the Ministry of Science and Technology says aerosols, dust and clouds reduce solar energy generation from photovoltaic and rooftop solar installations. That study was done in the central Himalaya, not in UP.
- A 2022 study in the journal Environmental Science & Technology says particle pollution "scatters and absorbs" sunlight before it reaches the panels, and that particles settling on the panels block more. It found this dimming largest over highly polluted regions, naming the Indo-Gangetic Plain.
This article does not give a number of fog days for Lucknow or Shahjahanpur, because no official count for either city was found.
What the model averages hide
- Single days vary a lot. UPNEDA's FAQ says daily generation depends on temperature and sunlight and "may not be the same every day". The table shows the average day of each month, over 19 years.
- Some winters are worse. In PVGIS's own 2005 to 2023 record, the sunlight on a 26° panel in the worst January was about 16% below the January average in Lucknow (January 2015) and about 19% below in Shahjahanpur (January 2022). Individual days within a month can fall much further. These percentages are estimates from PVGIS's monthly data.
- The weather data is coarse. PVGIS's satellite data does not cover these two cities, so it uses ERA5, a "reanalysis". That is a long-term weather record rebuilt by re-running weather models for past years and correcting them with real measurements. The JRC says reanalysis data is generally less accurate than its satellite-based data, and it gives about one value every 25 to 30 km.
- Your roof is not in the model. PVGIS counts shade from hills and mountains only, not from nearby buildings, water tanks or trees. The JRC lists dust and dirt, and partial shade, among effects its calculation does not include, beyond the general 14% loss allowance for cables, the inverter, dirt and ageing.
What to do in winter
Let net metering carry your surplus
Under net metering, your meter counts the units you send to the grid (export) and the units you take from it (import). UPPCL's FAQ says that if export is more than import in a month, the leftover units are carried forward to the next month and shown on the bill as "Closing Surplus Solar Units". This runs over the financial year, April to March.
So surplus from earlier months in the same financial year can cover a winter month in which you import more than you export. Units still left at the end of March are not carried into April. They are credited on the April bill at a set rate per unit. Fixed charges and electricity duty are payable on every bill, whatever your solar makes. Our net metering guide for UP explains the meter and the bill.
Keep the panels clean
UPNEDA's FAQ says dust, bird droppings and other debris reduce generation. How often to clean depends on local conditions, and on average panels need to be cleaned and rinsed with water every 15 days. The JRC notes that how long dust stays on panels depends on rainfall and on the panels' tilt. Particles from winter haze can settle on panels too.
MNRE's model agreement for PM Surya Ghar puts 5 years of comprehensive maintenance in the vendor's scope, and asks the vendor to teach you the best way to clean the panels. Ask your vendor to show you how to clean them safely.
Do not size the system for winter alone
- Winter is not the weak season for a tilted system in the model. December and January sit close to the yearly average, so a system sized on your yearly use already accounts for them.
- Extra panels mostly add year-end surplus. Surplus left at the end of March is credited at a set rate, not carried forward, so a system made bigger for a few foggy weeks will mostly add units that are paid out that way.
- Your sanctioned load sets a ceiling. UPNEDA's FAQ says the maximum capacity you can install equals your sanctioned load, and shade-free roof area can limit it further.
To start from your own use, our solar size calculator works out a system size from your monthly units.
Judge output over weeks, not one foggy morning
A few low days in a foggy spell are expected. Compare your system's units over a whole month with the model figure for that month, keeping in mind shade on your roof and the tilt of your panels. If output stays well below the model across clear days as well, ask your vendor to check the system. Under MNRE's model agreement, maintenance for the first 5 years is the vendor's job.
Get your roof checked
If you want to know what your own roof can produce, send a photo of your roof and your latest electricity bill on WhatsApp to +91 92609 40733. We will arrange a site survey and check the roof for shade.
Related guides:
Sources
- European Commission, Joint Research Centre, PVGIS 5.3 (PVcalc and MRcalc tools; Lucknow 26.85 N, 80.95 E and Shahjahanpur 27.88 N, 79.91 E; 1 kWp, 14% loss, tilt 26°, facing south; PVGIS-ERA5 data 2005 to 2023)re.jrc.ec.europa.eu · Accessed 21 November 2026
- European Commission, Joint Research Centre, "PVGIS 5 user manual" (radiation databases, system loss, horizon)joint-research-centre.ec.europa.eu · Accessed 21 November 2026
- European Commission, Joint Research Centre, "Data sources & calculation methods" (reanalysis data and its accuracy, atmospheric losses, effects not included)joint-research-centre.ec.europa.eu · Accessed 21 November 2026
- NOAA Global Monitoring Laboratory, "Solar Calculation Details" (method used for the day length and sun height estimates)gml.noaa.gov · Accessed 21 November 2026
- India Meteorological Department, MAUSAM, vol. 77, no. 3 (July 2026), R. R. Kumar and K. A. Sarkar, "A study on the characteristics of fog over Agartala Airport"mausamjournal.imd.gov.in · Accessed 21 November 2026
- India Meteorological Department, press release, 28 December 2025 (dense fog over Uttar Pradesh)mausam.imd.gov.in · Accessed 21 November 2026
- Press Information Bureau, Ministry of Science & Technology, "Impact of Aerosols and Clouds on Solar Energy generation leading to financial loss", 3 September 2021pib.gov.in · Accessed 21 November 2026
- F. Yao and P. I. Palmer, "Source Sector Mitigation of Solar Energy Generation Losses Attributable to Particulate Matter Pollution", Environmental Science & Technology, 2022pmc.ncbi.nlm.nih.gov · Accessed 21 November 2026
- UPNEDA, "FAQs related to rooftop solar", questions 1.8, 1.9, 1.10, 3.1 and 6.2upneda.org.in · Accessed 21 November 2026
- UPNEDA, "PM Surya Ghar: Muft Bijli Yojana Information Booklet"upneda.org.in · Accessed 21 November 2026
- Uttar Pradesh Power Corporation Ltd, "Smart Post-paid Meter FAQ" (Hindi), dated 27 May 2026, question 33smartapplink.uppcl.org · Accessed 21 November 2026
- Ministry of New and Renewable Energy, Guidelines for PM Surya Ghar: Muft Bijli Yojana, Central Financial Assistance to Residential Consumers, Annexure 2 (model vendor agreement, item 12) and Annexure 3 (technical specifications, mounting structure)mnre.gov.in · Accessed 21 November 2026
Related guides

BL Solar Solutions
Editorial Team
Published by BL Solar Solutions, a UPNEDA registered rooftop solar installer with 10+ years of experience in Uttar Pradesh.
Comments (0)
Share your thoughts and join the conversation
No comments yet
Be the first to share your thoughts!